Product characteristics
Dimensions [mm] 90 x 62 x 33.2
Inclination measurement
Number of measurement axes
2
Application
Application
High-precision inclination measurement in 2 axes for mobile and industrial applications
Electrical data
Operating voltage [V] 9.2…30 DC; (voltage output: 12…30 DC; IO-Link: 18…30 DC)
Current consumption [mA] 90; (24 V DC, 25 °C)
Max. current consumption [mA] 330; (9,2 V DC; -40 °C)
Protection class
III
Reverse polarity protection
yes
Reverse polarity protection
yes
Max. initialisation time [ms] 1000
Power-on delay time [s] 300; (warm-up time)
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 2
Outputs
Total number of outputs
4
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (programmable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C))
Number of analogue outputs
2
Analogue current output [mA] 4…20; (in case of a fault: 2 mA)
Max. load [Ω] 220; (220 (9,2…15 V) / 500 (15…30 V))
Analogue voltage output [V] 2…10; (in case of a fault: 1 V)
Min. load resistance [Ω] 1000; (10000 (12…13,5 V) / 1000 (13,5…30 V))
Precision analogue output [%] ≤ 1
Short-circuit protection
yes
Overload protection
yes
Measuring/setting range
Measuring principle
MEMS capacitive
Inclination measurement
Number of measurement axes
2
Angular range [°] ± 180
Limit frequency [Hz] 0.5…10; (parameterisable)
Vibration measurement
Measuring range of vibration
16; (± 2; ± 4; ±8 g parameterisable) g
3200 mm/s
Frequency range [Hz] 0.1…400
Number of measurement axes
X/Y/Z parameterisable
Accuracy / deviations
Accuracy [°] ≤ ± 0,5
Repeatability [°] ≤ ± 0,1
Resolution [°] 0.05
Temperature coefficient [1/K] ≤ ± 0,02
Software / programming
Parameter setting options
angle (X/Y) / vibration (Veff / aPeak); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode
yes
Required master port type
A
Process data analogue
2
Process data binary
2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation
DeviceID
Default
416
Operating conditions
Ambient temperature [°C] -40…85
Storage temperature [°C] -40…85
Protection
IP 65; IP 67; IP 68; IP 69K
Mechanical data
Weight [g] 410
Dimensions [mm] 90 x 62 x 33.2
Materials
housing: diecast zinc nickel-plated
Displays / operating elements
Display
operation
1 x LED, green
switch point
1 x LED, yellow
Accessories
Accessories (supplied)
Protective cover
Remarks
Pack quantity
1 pcs.
Electrical connection – digital
Connector: 1 x M12
Electrical connection – analogue
Connector: 1 x M12
Other data
Measuring/setting range
inclination measurement
min.
max.
switch point
SP1
[°]
-179.00
180.00
reset point
rP1
[°]
-180.00
179.00
switch point
SP2
[°]
-179.00
180.00
reset point
rP2
[°]
-180.00
179.00
Analogue start point
ASP1
[°]
-180.00
179.00
Analogue end point
AEP1
[°]
-179.00
180.00
Analogue start point
ASP2
[°]
-180.00
179.00
Analogue end point
AEP2
[°]
-179.00
180.00
In steps of
[°] 0.01
vibration measurement
min.
max.
switch point
SP1
[mm/s]
1
3200
reset point
rP1
[mm/s]
0
3199
Analogue start point
ASP3
[mm/s]
0
3199
Analogue end point
AEP3
[mm/s]
1
3200
In steps of
[mm/s] 1
vibration measurement
min.
max.
switch point
SP2
[mg]
1
16000
reset point
rP2
[mg]
0
15999
Analogue start point
ASP4
[mg]
0
15999
Analogue end point
AEP4
[mg]
1
16000
In steps of
[mg] 1