Product characteristics

Dimensions [mm] 90 x 62 x 33.2

Inclination measurement

Number of measurement axes
2

Application

Application
High-precision inclination measurement in 2 axes for mobile and industrial applications

Electrical data

Operating voltage [V] 9.2…30 DC; (voltage output: 12…30 DC; IO-Link: 18…30 DC)

Current consumption [mA] 100; (24 V DC, 25 °C)

Max. current consumption [mA] 380; (9,2 V DC; -40 °C)

Protection class
III

Reverse polarity protection
yes

Reverse polarity protection
yes

Max. initialisation time [ms] 1000

Power-on delay time [s] 300; (warm-up time)

Inputs / outputs

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 2

Outputs

Total number of outputs
4

Electrical design
PNP/NPN

Number of digital outputs
2

Output function
normally open / normally closed; (programmable)

Max. voltage drop switching output DC [V] 2.5

Permanent current rating of switching output DC [mA] 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C))

Number of analogue outputs
2

Analogue current output [mA] 4…20; (in case of a fault: 2 mA)

Max. load [Ω] 220; (220 (9,2…15 V) / 500 (15…30 V))

Analogue voltage output [V] 2…10; (in case of a fault: 1 V)

Min. load resistance [Ω] 1000; (10000 (12…13,5 V) / 1000 (13,5…30 V))

Precision analogue output [%] ≤ 1

Short-circuit protection
yes

Overload protection
yes

Measuring/setting range

Measuring principle
MEMS capacitive

Inclination measurement

Number of measurement axes
2

Angular range [°] ± 45

Limit frequency [Hz] 0.5…10; (parameterisable)

Accuracy / deviations

Accuracy [°] ≤ ± 0,01

Repeatability [°] ≤ ± 0,01

Resolution [°] 0.01

Temperature coefficient [1/K] ≤ ± 0,0008

Software / programming

Parameter setting options
angle (X/Y); hysteresis / window; switch points; switching logic; fault indication; self-test; current/voltage output

Interfaces

Communication interface
IO-Link

Transmission type
COM2 (38,4 kBaud)

IO-Link revision
1.1

SDCI standard
IEC 61131-9 CDV

Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis

SIO mode
yes

Required master port type
A

Process data analogue
2

Process data binary
2

Min. process cycle time [ms] 5

Supported DeviceIDs

Type of operation
DeviceID

Default
416

Operating conditions

Ambient temperature [°C] -40…85

Storage temperature [°C] -40…85

Protection
IP 65; IP 67; IP 68; IP 69K

Mechanical data

Weight [g] 451

Dimensions [mm] 90 x 62 x 33.2

Materials
housing: diecast zinc nickel-plated

Displays / operating elements

Display

operation
1 x LED, green

switch point
1 x LED, yellow

Accessories

Accessories (supplied)

Protective cover

Remarks

Pack quantity
1 pcs.

Electrical connection – digital

Connector: 1 x M12

Electrical connection – analogue

Connector: 1 x M12

Other data

Measuring/setting range

inclination measurement

min.
max.

switch point
SP1
[°] -89.00
90.00

reset point
rP1
[°] -90.00
89.00

switch point
SP2
[°] -89.00
90.00

reset point
rP2
[°] -90.00
89.00

Analogue start point
ASP1
[°] -90.00
89.00

Analogue end point
AEP1
[°] -89.00
90.00

Analogue start point
ASP2
[°] -90.00
89.00

Analogue end point
AEP2
[°] -89.00
90.00

In steps of

[°] 0.01