Features
Light source
LED
Type of light
Visible red light
Scanning range
10 m
Number of beams
1
Detection capability
30 mm
Optical axis
Axial
Response time
0.2 ms
Response time
0.2 ms + Test device response time
Safety-related parameters
Type
Type 4 (IEC 61496-1) 1)
Safety integrity level
SIL3 (IEC 61508) 1)
SILCL3 (EN 62061) 1)
Category
Category 4 (EN ISO 13849) 1)
Performance level
PL e (EN ISO 13849) 1)
PFHD (mean probability of a dangerous failure per hour)
8.1 x 10-10 (EN ISO 13849) 1)
TM (mission time)
20 years (EN ISO 13849)
1) Only in combination with an appropriate test device, e.g., Flexi Classic or Flexi Soft.
Interfaces
Connection type
Male connector M12, 4-pin, straight
Display elements
LED
Fieldbus, industrial network
Integration via Flexi Soft safety controller
CANopen 1)
DeviceNet™
EtherCAT®
EtherNet/IP™
Modbus TCP
PROFIBUS DP
PROFINET
1) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data – Operating data
Protection class
III (IEC 61140)
Power consumption
30 mA / 20 mA
Electrical data – Switching output
Current-carrying capacity per OSSD
≤ 70 mA
Mechanical data
Design
Cylindrical
Dimensions (diameter x length)
M18 x 97.7 mm
Housing material
Plastic
Lens material
Glass
Weight
30 g
Ambient data
Enclosure rating
IP67 (EN 60529)
Ambient operating temperature
–40 °C … +55 °C
Storage temperature
–40 °C … +75 °C
Air humidity
15 % … 95 %, Non-condensing
Vibration resistance
IEC 60068-2-6
Shock resistance
10 g, 16 ms (IEC 60068-2-29)
Other information
Light source
LED
Type of light
Visible red light
Wave length
660 nm
Aperture angle/receiving angle
± 2.5° / ± 2.5°