Model
KV-NC4TP
Temperature input unit
Number of inputs
4 *1
Input
Thermocouple, Platinum resistance thermometer
Input range
Thermocouple
K: -270.0 to 1372.0°C -454 to 2501.6°F
J: -210.0 to 1200.0°C -346 to 2192°F
T: -270.0 to 400.0°C -454 to 752°F
E: -270.0 to 1000.0°C -454 to 1832°F
N: -270.0 to 1300.0°C -454 to 2372°F
R: -50.0 to 1768.0°C -58 to 3214.4°F
S: -50.0 to 1768.0°C -58 to 3214.4°F
B: 0.0 to 1820.0°C 32 to 3308°F
WRe5-26: 0.0 to 2315.0°C 32 to 4199°F
Platinum resistance thermometer
Pt100: -200.0 to 850.0°C -328 to 1562°F
JPt100: -200.0 to 600.0°C -328 to 1112°F
Overall accuracy
Thermocouple
±(0.2% of F.S. +1°C 1.8°F) (at 25°C ±5°C 77°F ±9°F)
±(0.4% of F.S. +1°C 1.8°F) (at 0 to 55°C 32 to 131°F)
Platinum resistance thermometer
±0.2% of F.S. (at 25°C ±5°C 77°F ±9°F)
±0.4% of F.S. (at 0 to 55°C 32 to 131°F)
Allowable wiring resistance
100 Ω max./wire
(no variation allowed among three wires)
Conversion speed
125 ms/channel
Isolation method
Between input terminals and base unit:
Photocoupler/semiconductor relay/transformer isolation
Between channels: (When resistance thermometer is not used):
Semiconductor relay isolation;
(When resistance thermometer is used): No isolation
Special function
Channel skip, disconnection detection,
averaging (time average, count average, moving average),
special data offset, peak-/bottom-hold, alarm,
abnormal input setting
Internal current consumption
40 mA or less
Weight
Approx. 110 g
*1 Individual setting is possible for each channel.