Model
KV-NC16ETE
Expansion output unit
External connectionmethod
MOSFET output (With overcurrent protection function)*1*2
External connection method
European terminal block
Rated load
30 VDC, 0.2 A*3
Leakage current (when output is OFF)
100 μA or less
Residual voltage (at ON)
0.6 VDC or less
ON resistance
–
Common method
16 points/1 common (16 terminals)*4
Response time
OFF to ON
100 μs or less (with a load of 1 mA or more)
ON to OFF
200 μs or less (with a load of 1 mA or more)
Relay life
–
Relay replacement
Internal current consumption
30 mA or less
Weight
Approx. 120 g
*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 007 or 008 to 015.), until the cause of the problem is removed.
*2 Sink output types use MOSFET (N-ch) output. Source output types use MOSFET (P-ch) output.
*3 The rated load of each common terminal is 3.2 A
*4 The COM terminals are shorted internally.