Application
Application
short-circuit monitoring; Wire monitoring
Electrical data
Operating voltage tolerance [%] -15…25
Operating voltage [V] 24 DC
Current consumption [mA] 0,7 // 40 V DC / 2 A; (ohmic resistance)
Switching frequency DC [Hz] 10
Operating conditions
Ambient temperature [°C] -20…60
Protection
IP 20
Mechanical data
Weight [g] 164.5
Switching cycles mechanical
10 million
Displays / operating elements
Display
switching status
LED, yellow
operation
LED, green
function
LED, red
Remarks
Remarks
Caution The control monitor must be mounted outside the hazardous area.
Free terminals must not be used.
Pack quantity
1 pcs.
Electrical connection
Connection
terminals: …2.5 mm²
Other data
Maximum values for control circuit
in protection rating intrinsic safety
[EEx ia] IIC
[EEx ia] IIB
[EEx ib] IIC
[EEx ib] IIB
Voltage [V]
10.5
10.5
10.5
10.5
Current [mA]
13
13
13
13
Power [mW]
34
34
34
34
External inductance [mH]
210
840
210
840
External capacitance [µF]
2.41
16.8
2.41
16.8