Model
FD-GU1
System
Switching type
Input supply voltage
100 to 240 VAC; +10%/−15% (50/60 Hz)
Output voltage
24 VDC ±5%
Overvoltage category
ll
Ripple noise
260 mV (p-p) or lower
Output capacity
9.1 W (0.38 A) (Class 2)
Power consumption
100 VAC: 0.3 A or lower; 200 VAC: 0.2 A or lower
Pollution degree
2
Withstand voltage
3000 VAC, 1 minute (between input and output, between all external terminals and case)
Momentary interruption
20 ms or lower
Wiring specifications
AC input: power supply M4 terminal block, 2 poles; Analog output: M3 terminal block, 2 poles; DC output: M12 4-pin connector
Protection circuit
Protection against power supply surge, protection against output short-circuiting
Main unit size
63 2.48″ × 240 9.45″ × 40 1.57″ mm
Environmental resistance
Enclosure rating
IP65/67 (IEC60529)
Ambient temperature
-20 to +50ºC -4 to 122°F (no freezing)
Relative humidity
5 to 90%RH (no condensation)
Vibration resistance
10 to 500 Hz power spectral density: 0.816 G2/Hz in X, Y, Z axis directions
Shock resistance
Shock resistance 50 m/s2; 16 ms pulses, 1000 times each for X, Y, and Z axes
Material
PBT
Weight
Approx. 400 g