Technical data
FC3151-0000
FC3151-0002
Fieldbus
PROFIBUS DP (standard), PROFIBUS DP-V1 (Cl. 1+2: acyclic services, alarms), DP-V2, PROFIBUS MC (equidistant)
PC interface
Mini PCI
Number of fieldbus channels
1
Data transfer rates
9.6 kbaud…12 Mbaud
Bus interface
device-specific in the respective Industrial PC housing
Cycle time
differing DP cycle times per slave are possible using the CDL concept
Hardware diagnosis
device-specific in the respective Industrial PC housing
Bit width in the process image
per channel total max.: 3 kbyte input and output data
NOVRAM
–
128 kbytes
Dimensions
59.75 mm x 50.95 mm (type III A)
Operating temperature
0…+55 °C
Driver
TwinCAT I/O and higher levels