Technical data
EP3744-1041
Protocol
EtherCAT
Bus interface
2 x M8 socket, shielded, screw type
Number of inputs
4 x pressure, 6 x digital
Number of outputs
2 x digital
Connection method
digital signals: 4-pin M8; pressure measurement: 6 mm fitting
Signal type
air pressure
Measuring range
0…7 bar (0…100 psi)/ -7…7 bar (-100…100 psi)
Resolution
1 mbar per digit
Measuring error
3 %
Conversion time
~ 3.5 ms
Distributed clocks
yes
Input filter
10 µs (for digital inputs)
Specification
EN 61131-2, type 1/3
Max. output current
0.5 A per channel, individually short-circuit proof
Load type
ohmic, inductive, lamp load
Short-circuit current
typ. 1.5 A
Sensor supply
from load supply voltage, max. 0.5 A, short-circuit proof in total
Current consumption from US
120 mA
Power supply connection
feed: 1 x M8 male socket, 4-pin; downstream connection: 1 x M8 female socket, 4-pin
Electrical isolation
500 V
Special features
direct pressure measurement at the machine
Operating/storage temperature
-25…+60 °C/-40…+85 °C
Vibration/shock resistance
conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission
conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.
IP 65/66/67 (conforms to EN 60529)/variable
Approvals/markings
CE, UL