EL6900
Specification
link unit between safe input and output signals
Protocol
TwinSAFE/Safety over EtherCAT
Cycle time
approx. 500 µs/according to project size
Fault response time
? watchdog time (parameterizable)
Current consumption power contacts
–
Current consumption E-bus
typ. 188 mA
Installation position
horizontal
Safety standard
DIN EN ISO 13849-1:2008 (Cat. 4, PL e) and EN 61508:2010 (SIL 3)
Weight
approx. 50 g
IP protection class
IP 20
Ex marking
II 3 G Ex nA IIC T4 Gc