Technical data
EL5072
Technology
inductive sensor interface
Input connections
LVDT (ratiometric & differential), inductive half bridge, RVDT
Number of channels
2
Distributed clocks
yes, save timestamp for position value via digital input
Excitation voltage Uexc
0.5 Vrms to 7 Vrms (1.5 VPP to 20 VPP), joint source for both channels
Total excitation current
max. 50 mArms (140 mAPP)
Excitation frequency (sinus)
1 kHz up to 20 kHz, adjustable
Current consumption power contacts
typ. 40 mA + load
Resolution
24 bit, 32 bit presentation
Measuring signal range USIG
max. 7 Vrms (automatic adjustment)
Conversion time
100 µs/10 ksps at max. 13 kHz
Electrical isolation
500 V (E-bus/field potential)
Current consumption E-bus
typ. 200 mA
Special features
short circuit, overload and amplitude error detection per channel, digital input for setting and storing position value
Weight
approx. 60 g
Operating/storage temperature
0…+55 °C/-25…+85 °C
Relative humidity
95 %, no condensation
Vibration/shock resistance
conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission
conforms to EN 61000-6-2/EN 61000-6-4
Protect. class/installation pos.
IP 20/variable
Approvals/markings
CE