Technical data
EL5002, ES5002
Technology
SSI encoder interface
Number of channels
2
Encoder connection
D+, D-, Cl+, Cl-
Encoder operating voltage
external e.g. EL91xx
Signal output (pulse)
difference signal (RS422)
Signal input (data)
difference signal (RS422)
Power supply
24 V via power contacts
Data transfer rates
variable up to 1 MHz, 250 kHz default
Serial input
variable up to 32 bit, 24 bit default
Data direction
read
Current consumption power contacts
typ. 20 mA + load
Current consumption E-bus
typ. 130 mA
Distributed clocks
yes
Special features
adjustable baud rate, coding and data length, power fail bit activatable
Weight
approx. 55 g
Electrical isolation
500 V (E-bus/field potential)
Operating/storage temperature
-25…+60 °C/-40…+85 °C
Relative humidity
95 %, no condensation
Vibration/shock resistance
conforms to EN 60068-2-6/EN 60068-2-27
Protect. class/installation pos.
IP 20/variable
EMC immunity/emission
conforms to EN 61000-6-2/EN 61000-6-4
Approvals/markings
CE, UL, ATEX
Pluggable wiring
for all ESxxxx terminals
Ex marking
II 3 G Ex nA IIC T4 Gc