Product characteristics
Electrical design
PNP
Output function
normally open
Sensing range [mm] 30…120
Housing
cylindrical
Dimensions [mm] Ø 164 / L = 63
Electrical data
Operating voltage [V] 10…36 DC
Current consumption [mA] 15; (24 V)
Protection class
II
Reverse polarity protection
yes
Outputs
Electrical design
PNP
Output function
normally open
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 3
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Detection zone
Sensing range [mm] 30…120
Sensing range adjustable
yes
Factory setting sensing range [mm] 120
Real sensing range Sr [mm] 120 ± 10 %
Accuracy / deviations
Correction factor
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr]