Cảm biến quang Keyence PR-G41CBL

SKU: PR-G41CBL
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Mã sản phẩm: PR-G41CBL Danh mục: , ,
Liên hệ báo giá

Model
PR-G41CBL

Type
Diffuse reflective (Long distance)

Shape
Threaded mount type

Output
NPN+PNP

Cable connection
M12 connector (4 pin)

Detecting distance
500 mm19.685″

Number of control outputs
2 (NPN+PNP)

Output operation
Output 1
Light-ON

Output 2
Dark-ON*1

Response time
0.5 ms

Sensitivity adjustment
Five-turn trimmer

Spot diameter
ø20 mm ø0.79″ max.
(at 300 mm 11.81″)

Light source
4 elements, Point light source red LED (650 nm)

Light interference prevention function
2

Indicator lamp
7 segment display (0 to 999), output indicator (yellow)

Control output
NPN + PNP open collector
30 VDC or less, 100 mA or less
Residual voltage: 1.2 V or less at less than 10 mA, 2 V or less at 10 to 100 mA

Stop emission input
―

Protection circuit
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Rating
Power voltage
10 to 30 VDC, including Ripple (P-P) 10 %

Power consumption
450 mW max. (15 mA max. at 24 V, 21 mA max. at 12 V)

Environmental resistance
Enclosure rating
IP68 (IEC60529), IP69K (DIN40050-9), 4, 6, 13 (NEMA250)*2

Insulation resistance
20 MΩ or more (500 VDC)

Ambient light
Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature
-20 to +70 °C -4 to 158 °F (No freezing)*3

Storage temperature
-20 to +70 °C -4 to 158 °F

Relative humidity
35 to 85 % RH (No condensation)

Withstand voltage
1,000 VAC, 50/60 Hz, 1 min

Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions

Shock resistance
1,000 m/s2, 6 times in each of the X, Y, and Z directions

Accessories
Instruction Manual, M18 nut, Lock washer

Weight
Approx. 45 g

*1 Output 2 is not available on the threaded mount type or M8 3-pin type.
*2 For the connector type, the enclosure rating varies depending on the cable that is used.
*3 When the ambient temperature is 60 °C 140 °F or higher, the device should be powered with no more than 24 VDC and 50 mA.