Product characteristics
Number of inputs and outputs
Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
250…1600 °C
482…2912 °F
Application
Application
tempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling
Electrical data
Operating voltage [V] 18…32 DC; (to SELV/PELV)
Current consumption [mA] 600 °C)
Software / programming
Adjustment of the switch point
programming buttons
Parameter setting options
analogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
yes
Required master port type
A
Process data analogue
16
Process data binary
1
Min. process cycle time [ms] 3.6
Supported DeviceIDs
Type of operation
DeviceID
Default
717
Operating conditions
Ambient temperature [°C] 0…65
Storage temperature [°C] -20…80
Max. relative air humidity [%] 95; (non condensing)
Protection
IP 65
Mechanical data
Weight [g] 465
Housing
threaded type
Dimensions [mm] M30 x 1.5
Thread designation
M30 x 1.5
Materials
threaded sleeve: stainless steel (1.4305 / 303); polyester
Lens material
tempered optical glass
Displays / operating elements
Display
Display unit
2 x LED, yellow
switching status
1 x LED, yellow
function display
7-segment LED display, 4-digit
measured values
7-segment LED display, 4-digit
Operating elements
3
pushbuttons
Accessories
Accessories (supplied)
lock nuts: 2
Remarks
Remarks
Use a screened cable to protect infrared temperature sensors from interference.
The screen must be connected to the housing of the sensor via the connector.
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12