Product characteristics
 Number of inputs and outputs
 Number of digital outputs: 2 
 Factory setting
 hydrous media 
 Process connection
 threaded connection G 1/2 sealing cone 
Application
 Special feature
 Gold-plated contacts 
 Media
 Liquids; viscous media; powder 
 Recommended media
 water; hydrous media; oils; oil-based media; powder 
 Cannot be used for
 See the operating instructions, chapter “Function and features”. 
Probe length [mm] 253
Tank pressure [bar] -1…40
MAWP (for applications according to CRN) [bar] 40
Oil
Medium temperature [°C] -20…100
Medium temperature short time [°C] -20…150; (1 h)
Water
Medium temperature [°C] -20…100
Medium temperature short time [°C] -20…150; (1 h)
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA]

                                                      
                                                      
                                                      
                                                      
						
						
						
						
						
						
						
						
						
						
						
						
						
				
				
				
				
				
				