Model
FD-XS1E
Supported pipe materials
Metal pipes, Plastic pipes (soft/hard) *1
Supported fluids
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1
Supported fluid temperature
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)
Clamp set model
Plastic pipe/tube attachment
FD-XC1R1, FD-XC1R2
Metal pipe attachment
FD-XC1M*2
Maximum rated flow rate
1000 mL/min
Zero cut flow rate
50 mL/min*3 (variable, default)
Display resolution
Instantaneous flow rate
1/10 mL/min (Displayed on controller)
Repeatability
Response time 50 ms: ±20 % of RD
Response time 500 ms: ±15 % of RD
Hysteresis
Variable
Display method
Status indicator
Environmental resistance
Enclosure rating
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4
Ambient temperature
0 to 60 °C 32 to 140 °F (No freezing)
Relative humidity
35 % to 85 %RH (No condensation)
Vibration resistance
10 to 55 Hz, double amplitude 1.5 mm 0.06 “, 2 hours each for X,Y,Z direction
Shock resistance
50 G 11 ms 3 times each for X,Y,Z direction
Material
Sensor head
Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM
Clamp set
For plastic pipe
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7
For metal pipe
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7
Weight
Approx. 230 g
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1E: approx. 0.5 mm 0.02″, FD-XS8E: approx. 1 mm 0.04″, FD-XS20E: approx. 1 0.04″ to 2 mm 0.08″. FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 The connector part of the sensor head cable is IP65/IP67.