Cảm biến lưu lượng Keyence FD-Q32C

Sensor Main Unit 25A/32A Type
SKU: FD-Q32C
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Mã sản phẩm: FD-Q32C Danh mục: , ,
Liên hệ báo giá

Model
FD-Q32C

Supported pipe diameter
1″ (25 A), ø28 to ø37 (mm)
1 1/4″ (32 A), ø37 to ø44 (mm)

Supported pipe materials
Metal pipe/Resin pipe*1

Supported fluids
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow
1″ (25 A): 200 L/min, 52.8 G/min
1 1/4″ (32 A): 300 L/min, 79.3 G/min

Zero cut flow rate
5 L/min (Default)*3

Display method
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle
Approx. 3 Hz

Display resolution
0.1/ 1 (Default :1) (L/min)

Response time
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit
Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis
Variable

Integrated flow unit display
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L)

Integrated flow data storage cycle
Save to memory every 10 seconds

Memory backup
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector
M12 4-pin connector

Input/Output (Selectable)
Output (ch.1/ch.2)
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.1/ch.2)
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply
Power voltage
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption
130 mA or less (Load current excluded)*6

Environmental resistance
Enclosure rating
IP65/IP67 (IEC60529)

Ambient temperature
-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity
35 to 85 % RH (No condensation)

Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions

Shock resistance
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material
Sensor main unit
PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface
Rubber

Mounting bracket
SUS304/PA/POM/SUSXM7

Weight
Approx. 530 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.