Cảm biến lưu lượng Keyence FD-H47F

Flow Sensors Hose model ø33–47.9
SKU: FD-H47F
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Mã sản phẩm: FD-H47F Danh mục: , ,
Liên hệ báo giá

Model
FD-H47F

Type
Hose model

Supported pipe diameter
ø33–47.9 ø1.299″-1.886″

Supported pipe materials
Soft plastic piping, all hoses (braided hoses, pressure-resistant rubber hoses, etc.)*1

Supported fluids
All fluids (water, oil, chemicals, etc.)*1

Supported fluid temperature
0–100°C 32–212°F (no freezing on pipe surface)*2

Maximum rated flow
300 L/min
79.3 gal/min

Zero cut flow rate
2.0 L/min
0.5 gal/min (variable, initial value)

Detection principle
Delta TOF

Function for automatic correction for speed of sound in liquid

Display
QVGA 2.0 model: color LCD, status indicator light

Display update cycle
Approx. 10 times/second

Display resolution
Instantaneous flow
0.01/0.1/1 (L/min) (default value: 1)

Integrated flow
0.01/0.1/1 (L) (default value: 1; up to 8 digits)

Response time
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s

Measurement accuracy

Repeatability
0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*4

Hysteresis
Variable

Flow units
L/min m3/h G/min

Pulse output increments (L)
0.02–999.99

Pipe temperature measurement accuracy

Network support
IO-Link*5

Heat calculation function
Unit
MJ/h kW kBTU/h*6

Display resolution
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*6

Pulse output increments (MJ)
0.02–999.99*6

Data accumulation
Accumulation period
Approx. 1 year

Data reading
USB2.0

Power I/O connector
M12 8-pin connector (male)

I/O (switchable)
Output (Ch1/2/3/4)
Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

External input (Ch2/3)
Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply
Power voltage
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

Current consumption
240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*7

Protection circuit
Protection against reverse power connection, power supply surges, output short circuits, and output surges

Environmental resistance
Enclosure rating
IP65/67 (IEC 60529)*8

Ambient temperature
Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2

Relative humidity
35–85% RH (no condensation)

Vibration resistance
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes

Material
Display unit
Body: PPS/PET/POM; Display window: PAR

Sensor head
Body: PPS/PET/PAR/SUS304; Cable: PVC
Sensor element: special rubber; Mounting bracket: PPS/PBT/POM/SUS304/SUSXM7

Weight
approx. 1130 g 39.86 oz

*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.
*4 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*5 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*6 Can be used when two temperature sensors (sold separately) are connected.
*7 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*8 When a USB connection is in use, IP65/67 compliance is impaired.