Product characteristics
Number of inputs and outputs
Number of analogue outputs: 2
Measuring range
5…300 l/min
0.3…18 m³/h
80…4755 gph
1.3…79.3 gpm
Process connection
threaded connection 1 1/2″ NPT DN40
Application
Special feature
Gold-plated contacts
Application
empty pipe detection; for industrial applications
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: 15 l/min) / ± 1 (77 °F; Q > 4 gpm)
Response times
Flow monitoring
Response time [s] 0.35; (dAP = 0)
Damping for the switching output dAP [s] 0…5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 3 (Q > 15 l/min) / T09 = 3 (Q > 4 gpm)
Software / programming
Parameter setting options
display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature
-10…60 °C
14…140 °F
Storage temperature
-25…80 °C
-13…176 °F
Protection
IP 65; IP 67
Mechanical data
Weight [g] 2745
Materials
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM
Process connection
threaded connection 1 1/2″ NPT DN40
Displays / operating elements
Display
Display unit
6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)
function display
1 x LED, yellow (10³)
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit
l/min; m³/h; gpm; gph; °C; °F
Accessories
Accessories (supplied)
Label
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Contacts: gold-plated