Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.2…100 l/min
0.01…6 m³/h
Process connection
threaded connection G 1 DN25 flat seal
Application
Special feature
Gold-plated contacts
Application
empty pipe detection; totaliser function; for industrial applications
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: 5 l/min)
Response times
Flow monitoring
Response time [s] 0.15; (dAP = 0)
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 30 (Q > 5 l/min)
Software / programming
Parameter setting options
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection
Operating conditions
Ambient temperature [°C] -10…60
Storage temperature [°C] -25…80
Protection
IP 67
Mechanical data
Weight [g] 629
Materials
stainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM/X
Materials (wetted parts)
stainless steel (1.4404 / 316L); PEEK; EPDM/X
Process connection
threaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit
6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Contacts: gold-plated