Product characteristics
Probe length L [mm] 12
Process connection
M12 x 1
Application
Media
Liquids; Gases
Medium temperature [°C] -20…70
Pressure rating [bar] 30
Liquids
Medium temperature [°C] -20…70
Gases
Medium temperature [°C] -20…70
Electrical data
Connection to control monitor
VS2000 Exi (PTB 01 ATEX 2075)
Measuring/setting range
Probe length L [mm] 12
Liquids
Setting range [cm/s] 3…300
Greatest sensitivity [cm/s] 3…60
Gases
Setting range [cm/s] 200…2000
Greatest sensitivity [cm/s] 200…800
Accuracy / deviations
Temperature gradient [K/min] 15
Response times
Response time [s] 1…10
Liquids
Response time [s] 1…10
Gases
Response time [s] 1…10
Operating conditions
Ambient temperature [°C] -20…70
Protection
IP 67
Safety classification
Max. internal capacitance [nF] 0.4
Max. internal inductance [µH] 2
Temperature class
T4
Mechanical data
Weight [g] 110.5
Housing
threaded type
Dimensions [mm] M12 x 1
Thread designation
M12 x 1
Materials
stainless steel (1.4404 / 316L)
Materials (wetted parts)
stainless steel (1.4404 / 316L)
Process connection
M12 x 1
Installation length EL [mm] 27
Remarks
Remarks
In principle, the type test according to 94/9/EC (ATEX) only takes atmospheric conditions into account (0.8…1.1 bar).
For pressures outside this range use must be assessed and approved by the user.
Adhere to the operating instructions and the type test certificate.
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Maximum cable length: 100 m