Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.3…95.2 m/s
3…700 m³/h
0.04…11.66 m³/min
Process connection
threaded connection R 2 DN50
Application
Application
for industrial applications
Media
compressed air
Note on media
air quality ISO 8573-1
class 141
class 344
Medium temperature [°C] 0…60
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA]