Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Process connection
threaded connection G 1/2
Application
Special feature
Gold-plated contacts
Media
water; glycol solutions; air; oils
Note on media
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C] -20…90
Pressure rating [bar] 100
MAWP (for applications according to CRN) [bar] 85
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] 70 °C)
Temperature gradient [K/min] 100
Accuracy
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20…70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.)
Repeatability
0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Temperature monitoring
Temperature drift
± 0,005 K/°C
Accuracy [K] ± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s)
Response times
Flow monitoring
Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09 [s] 1,5 (T09); (water; flow velocity: 0,3…3 m/s)
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode
yes
Required master port type
A
Process data analogue
2
Process data binary
2
Min. process cycle time [ms] 3
Supported DeviceIDs
Type of operation
DeviceID
Factory setting / ModE = (REL)
535
ModE = (LIQU)
540
ModE = (GAS)
547
Operating conditions
Ambient temperature [°C] -40…80
Storage temperature [°C] -40…100
Protection
IP 65; IP 67
Mechanical data
Weight [g] 324
Materials
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts)
stainless steel (1.4404 / 316L); Gasket: FKM
Process connection
threaded connection G 1/2
Displays / operating elements
Display
Display unit
6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Contacts: gold-plated