Product characteristics
Output function
normally open / normally closed; (selectable)
Sensing range [mm] 20
Housing
threaded type
Dimensions [mm] M30 x 1.5 / L = 90
Electrical data
Operating voltage [V] 30…250 AC / 20…250 DC
Rated insulation voltage [V] 250
Protection class
II
Reverse polarity protection
yes
Max. power-on delay time [ms] 700
Outputs
Output function
normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 8
Max. voltage drop switching output AC [V] 10
Minimum load current [mA] 5
Max. leakage current [mA] 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC)
Permanent current rating of switching output AC [mA] 100; (150 (…40 °C))
Permanent current rating of switching output DC [mA] 100; (150 (…40 °C))
Short-time current rating of switching output [mA] 1000; (20 ms / 0,5 Hz)
Switching frequency AC [Hz] 10
Switching frequency DC [Hz] 10
Short-circuit proof
no
Overload protection
no
Detection zone
Sensing range [mm] 20
Accuracy / deviations
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -20…20
Software / programming
Parameter setting options
7 output hold times programmable; (1: 0 s; 2: 2 s; 3: 4 s; 4: 6 s; 5: 8 s; 6: 10 s; 7: 12 s)
Operating conditions
Ambient temperature [°C] -25…80
Note on ambient temperature
temperature of the sensing face: -25…110 °C
Protection
IP 65; IP 67
Mechanical data
Weight [g] 107.65
Housing
threaded type
Mounting
non-flush mountable
Dimensions [mm] M30 x 1.5 / L = 90
Thread designation
M30 x 1.5
Materials
housing: PBT; plug: PC; pushbuttons: TPE-U
Displays / operating elements
Display
switching status
1 x LED, yellow
Teach function
yes
Electronic lock
yes
Electrical connection
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting
Accessories
Accessories (supplied)
lock nuts: 2
Remarks
Remarks
Note:
Check the safe functioning of the unit after a short circuit.
Pack quantity
1 pcs.
Electrical connection – plug
Connector: 1 x 1/2″