Cảm biến điện dung IFM KI0064

SKU: KI0064
Hãng sản xuất: IFM
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

Mã sản phẩm: KI0064 Danh mục: ,
Liên hệ báo giá

Product characteristics

Output function
normally open / normally closed; (selectable)

Sensing range [mm] 20

Housing
threaded type

Dimensions [mm] M30 x 1.5 / L = 90

Electrical data

Operating voltage [V] 30…250 AC / 20…250 DC

Rated insulation voltage [V] 250

Protection class
II

Reverse polarity protection
yes

Max. power-on delay time [ms] 700

Outputs

Output function
normally open / normally closed; (selectable)

Max. voltage drop switching output DC [V] 8

Max. voltage drop switching output AC [V] 10

Minimum load current [mA] 5

Max. leakage current [mA] 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC)

Permanent current rating of switching output AC [mA] 100; (150 (…40 °C))

Permanent current rating of switching output DC [mA] 100; (150 (…40 °C))

Short-time current rating of switching output [mA] 1000; (20 ms / 0,5 Hz)

Switching frequency AC [Hz] 10

Switching frequency DC [Hz] 10

Short-circuit proof
no

Overload protection
no

Detection zone

Sensing range [mm] 20

Accuracy / deviations

Hysteresis [% of Sr] 1…15

Switch point drift [% of Sr] -20…20

Software / programming

Parameter setting options
7 output hold times programmable; (1: 0 s; 2: 2 s; 3: 4 s; 4: 6 s; 5: 8 s; 6: 10 s; 7: 12 s)

Operating conditions

Ambient temperature [°C] -25…80

Note on ambient temperature

temperature of the sensing face: -25…110 °C

Protection
IP 65; IP 67

Mechanical data

Weight [g] 107.65

Housing
threaded type

Mounting
non-flush mountable

Dimensions [mm] M30 x 1.5 / L = 90

Thread designation
M30 x 1.5

Materials
housing: PBT; plug: PC; pushbuttons: TPE-U

Displays / operating elements

Display

switching status
1 x LED, yellow

Teach function
yes

Electronic lock
yes

Electrical connection

Required protection
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting

Accessories

Accessories (supplied)

lock nuts: 2

Remarks

Remarks

Note:

Check the safe functioning of the unit after a short circuit.

Pack quantity
1 pcs.

Electrical connection – plug

Connector: 1 x 1/2″