Product characteristics
Output function
normally open
Sensing range [mm] 3…20
Housing
cylindrical
Dimensions [mm] Ø 34 / L = 81
Electrical data
Operating voltage [V] 20…250 AC/DC
Protection class
II
Reverse polarity protection
no
Outputs
Output function
normally open
Max. voltage drop switching output DC [V] 8
Max. voltage drop switching output AC [V] 10
Minimum load current [mA] 5
Max. leakage current [mA] 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC)
Permanent current rating of switching output AC [mA] 200; (for UL application: 250 / 100 DC)
Permanent current rating of switching output DC [mA] 200; (for UL application: 250 AC / 100 DC)
Short-time current rating of switching output [mA] 1500; (20 ms / 0,5 Hz)
Switching frequency AC [Hz] 25
Switching frequency DC [Hz] 40
Short-circuit proof
no
Overload protection
no
Detection zone
Sensing range [mm] 3…20
Sensing range adjustable
yes
Factory setting sensing range [mm] 20
Real sensing range Sr [mm] 20 ± 10 %
Operating distance [mm] 0…16.2
Accuracy / deviations
Correction factor
glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -15…15
Operating conditions
Ambient temperature [°C] -25…70
Protection
IP 65
Increased immunity
yes; (increased immunity to conducted radio frequency interference)
Mechanical data
Weight [g] 284.5
Housing
cylindrical
Mounting
non-flush mountable
Dimensions [mm] Ø 34 / L = 81
Materials
PBT
Displays / operating elements
Display
switching status
1 x LED, yellow
Electrical connection
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting
Accessories
Accessories (supplied)
Mounting clamps: 1
screwdriver: 1
head cap screw: 1
spring discs
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity
1 pcs.
Electrical connection
Connection
Cable: 2 m, PVC; 2 x 0.5 mm²