Product characteristics
Output signal
analogue signal
Measuring range
0…6 bar
0…87 psi
0…600 kPa
0…0.6 MPa
Process connection
threaded connection G 1/4 external thread (DIN EN ISO 1179-2)
Application
Measuring element
metallic thin film cell
Application
for mobile applications; for industrial applications
Media
liquids and gases
Medium temperature [°C] -40…125
Min. bursting pressure
200 bar
2900 psi
20 MPa
Pressure rating
15 bar
215 psi
1.5 Mpa
Note on pressure rating
static
Vacuum resistance [mbar] -1000
Type of pressure
relative pressure
Electrical data
Operating voltage [V] 8…36 DC
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s] 0.1
Inputs / outputs
Number of inputs and outputs
Number of analogue outputs: 1
Outputs
Output signal
analogue signal
Number of analogue outputs
1
Analogue current output [mA] 4…20
Max. load [Ω] (Ub – 8 V) / 21,5 mA
Short-circuit proof
yes
Overload protection
yes
Measuring/setting range
Measuring range
0…6 bar
0…87 psi
0…600 kPa
0…0.6 MPa
Accuracy / deviations
Repeatability [% of the span]