Product characteristics
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Measuring range
-0.125…2.5 bar
-125…2500 mbar
-1.8…36.25 psi
-12.5…250 kPa
Process connection
threaded connection 1/4″ NPT external thread
Application
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C] -25…80
Min. bursting pressure
50 bar
725 psi
5000 kPa
Pressure rating
20 bar
290 psi
2000 kPa
Vacuum resistance [mbar] -1000
Type of pressure
relative pressure
MAWP (for applications according to CRN)
20 bar
290 psi
2000 kPa
Electrical data
Operating voltage [V] 18…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] 50; (depends on lubrication, seal and pressure rating)
Process connection
threaded connection 1/4″ NPT external thread
Restrictor element integrated
no (can be retrofitted)
Displays / operating elements
Display
Display unit
3 x LED, green (bar, psi, kPa)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Remarks
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Contacts: gold-plated