Product characteristics
Output signal
analogue signal; IO-Link
Measuring range
-1…40 bar
-14.6…580.2 psi
-0.1…4 MPa
Process connection
threaded connection G 1/2 external thread sealing cone
Application
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Conditionally suitable for
use in gases at pressures > 25 bar only on request
Medium temperature [°C] -25…125; ( 0,9 m/s)
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor ED2: Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
SIO mode
no
Required master port type
A; (when pin 2 not connected: B)
Min. process cycle time [ms] 4.5
IO-Link resolution pressure [bar] 0.01
IO-Link resolution temperature [K] 0.2
IO-Link process data (cyclical)
function
bit length
pressure
16
temperature
16
device status
4
IO-Link functions (acyclical)
application specific tag; internal temperature
Supported DeviceIDs
Type of operation
DeviceID
Default
1018
Operating conditions
Ambient temperature [°C] -25…80
Storage temperature [°C] -40…100
Protection
IP 67; IP 68; IP 69K
Mechanical data
Weight [g] 252.1
Materials
stainless steel (1.4404 / 316L); PTFE; FKM
Materials (wetted parts)
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra