Model
FL-S001
Type
Sanitary type
Measurement range
200 to 2,000 mm 7.87″ to 78.74″
Specific conductive capacity of measurable media
2 or more*1
Resolution
1 mm 0.04″*2
Linearity
±3 mm ±0.12″*2
Temperature characteristics
0.1 mm/°C
Undetectable area
In the case of water
Top side
25 mm 0.98″
Bottom side
45 mm 1.77″ max.*3
In the case of oil
Top side
50 mm 1.97″
Bottom side
65 mm 2.56″ max.*3
Judgment output response time
0.4 s minimum
Probe horizontal torque
6 N m
Tank pressure
-0.1 to +1 Mpa
Connection port
2S ferrule
Control output
Judgment output/alarm output
NPN/PNP open collector (selectable), 30 VDC max., 50 mA max. for each
Residual voltage: 2 V max. for NPN, 2.5 V max. for PNP, N.O./N.C. switchable
Analog output
4 to 20 mA, maximum load resistance: 350 Ω (Response time: 0.1 s after comparator output determined [90 % response])
Ripple when target remains stationary (P-P) 2 % of F.S. max.
Network compatibility
IO-Link*4
Analog output accuracy
Resolution
1 mm 0.04″
Zero accuracy
±0.1 mA (Zero point = 4 mA)
Full scale accuracy
±0.2 mA (full scale = 20 mA)
Applicable cable
8-pin M12 connector
Rating
Power voltage
10 to 30 VDC, ripple (P-P) 10% included, Class 2 or LPS
Current consumption
300 mA max. (at 10 V)/120 mA max. (at 30 V) (excluding load)
Environmental resistance
Enclosure rating
IP67
Ambient temperature
-20 to +60 °C -4 to +140°F
Relative humidity
35 to 85 % RH (No condensation)
Operating medium temperature
-20 to +150 °C -4 to 302 °F
Vibration resistance
10 to 55 Hz, 0.75 mm 0.03″ double amplitude in X, Y and Z directions, 2 hours respectively
Shock resistance
300 m/s2 in 6 directions, 3 times respectively
Material
Liquid end materials
Sheath: PFA
Probe: SUS304
(do not connect this directly)
Case
Metal section of the housing: SUS304
Plastic section of the housing: PBT, PAR, HNBR, EPDM, PTFE, PPSU, PET
Weight
670 g
*1 These values were measured at the position of 100 mm 3.94″ or less from the wall of a metal tank. Contact KEYENCE for the case of a plastic tank.
*2 These values were measured under the following conditions.
Medium: Water, Tank material: Metal, Linearity range: Between 6 cm 2.36″ from the top and 1 cm 0.39″ from the bottom, Average time: 4 s
*3 For the sanitary/plastic types, the undetectable area from the bottom end varies depending on the length of the probe.
*4 Compatible with IO-Link Specification V1.1/COM 2 (38.4 kbps).