Model
FD-XS20
Supported pipe materials
Metal pipes, Plastic pipes (soft/hard) *1
Supported fluids
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1
Supported fluid temperature
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)
Clamp set model
Plastic pipe/tube attachment
FD-XC20R1, FD-XC20R2, FD-XC20R3, FD-XC20R4
Metal pipe attachment
FD-XC20M1, FD-XC20M2*2
Maximum rated flow rate
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “, ø 10.5 0.41 “: 0 to 15.00 L/min
Outer diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm) , ø 13.8 0.54 “: 0 to 20.00 L/min
Zero cut flow rate
0.10 L/min (standard), 40 mL/min (high resolution*3)*4 (variable, default)
Display resolution
Instantaneous flow rate
0.001/0.01/0.1 L/min (standard), 0.1/1/10 mL/min (high resolution*3) (Displayed on controller)
Shot amount
0.001/0.01/0.1 L (standard), 0.001/0.01/0.1/1 mL (high resolution*3) (Displayed on controller)
Repeatability
Plastic pipe/tube attachment
Response time: 50 ms
F.S.
± 0.1 %*5*6
Instantaneous flow rate
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “: ±15 mL/min
Outer diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm): ±20 mL/min*5*6
Response time: 500 ms
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “: ±4.7 mL/min
Outer diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm): ±6.3 mL/min*5
Metal pipe attachment
Response time: 50 ms
F.S.
±0.15 %*5*6
Instantaneous flow rate
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “, ø 10.5 0.41 “: ±23 mL/min
Outer diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm) , ø 13.8 0.54 “: ±30 mL/min*5*6
Response time: 500 ms
Outer diameter of pipe 3/8 ” (9.53 mm) , ø 10 0.39 “, ø 10.5 0.41 “: ±7.2 mL/min
Outer diameter of pipe ø 12 0.47 “, 1/2 ” (12.7 mm) , ø 13.8 0.54 “: ±9.5 mL/min*5
Hysteresis
Variable
Integrated unit display
0.01/0.1/1/10/100 L (standard), 0.1/1/10/100/1000/10000 mL (high resolution*3) (displayed on controller)
Display method
Status indicator
Environmental resistance
Enclosure rating
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *7
Ambient temperature
-10 to 60 °C (No freezing) 14 to 140 °F
Relative humidity
35 % to 85 %RH (No condensation)
Vibration resistance
10 to 55 Hz, double amplitude 1.5 mm 0.06 “, 2 hours each for X,Y,Z direction
Shock resistance
50 G 11 ms 3 times each for X,Y,Z direction
Material
Sensor head
Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM
Clamp set
For plastic pipe
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7
For metal pipe
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7
Weight
Approx. 260 g
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1: approx. 0.5 mm 0.02″, FD-XS8: approx. 1 mm 0.04″, FD-XS20: approx. 1 0.04″ to 2 mm 0.08″. FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 Only controllers with serial numbers beginning with “G” (FD-XA1/XA2/XA5) are supported.
*4 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*5 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range.
*6 The longer the response time is set, the more repeatability is improved. As a guideline, use √ (50 ms/response time) times.
*7 The connector part of the sensor head cable is IP65/IP67.