Product characteristics
Electrical design
PNP/NPN
Output function
normally open / normally closed; (selectable)
Sensing range [mm] 15
Housing
rectangular
Dimensions [mm] 40 x 40 x 120
Electrical data
Operating voltage [V] 10…55 DC
Reverse polarity protection
yes
Outputs
Electrical design
PNP/NPN
Output function
normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 4.6
Minimum load current [mA] 4
Max. leakage current [mA] 1
Permanent current rating of switching output DC [mA] 400
Switching frequency DC [Hz] 350
Short-circuit protection
yes
Overload protection
yes
Detection zone
Sensing range [mm] 15
Real sensing range Sr [mm] 15 ± 10 %
Accuracy / deviations
Correction factor
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr] 3…15
Switch point drift [% of Sr] -10…10
Operating conditions
Ambient temperature [°C] -25…80
Protection
IP 65
Mechanical data
Weight [g] 208.652
Housing
rectangular
Mounting
flush mountable
Dimensions [mm] 40 x 40 x 120
Materials
PPE
Displays / operating elements
Display
switching status
1 x LED, red
Remarks
Pack quantity
1 pcs.
Electrical connection – plug
Connection
Connector: 1 x M12