Product characteristics
Electrical design
PNP
Output function
normally open
Sensing range [mm] 4
Housing
rectangular
Dimensions [mm] 40 x 12 x 26
Electrical data
Operating voltage [V] 10…36 DC
Current consumption [mA] 15; (24 V)
Protection class
III
Reverse polarity protection
yes
Outputs
Electrical design
PNP
Output function
normally open
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 250
Switching frequency DC [Hz] 1300
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Detection zone
Sensing range [mm] 4
Real sensing range Sr [mm] 4 ± 10 %
Operating distance [mm] 0…3.24
Accuracy / deviations
Correction factor
steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -10…10
Operating conditions
Ambient temperature [°C] -20…60
Protection
IP 67
Mechanical data
Weight [g] 505.5
Housing
rectangular
Mounting
non-flush mountable
Dimensions [mm] 40 x 12 x 26
Materials
PBT
Displays / operating elements
Display
switching status
1 x LED, yellow
Remarks
Remarks
The sensor is a component for use in switch boxes suitable for hazardous areas.
Pack quantity
1 pcs.
Electrical connection
Connection
Cable: 10 m, PVC; 3 x 0.5 mm²