Product characteristics
Electrical design
PNP
Output function
normally open
Sensing range [mm] 4
Housing
rectangular
Dimensions [mm] 40 x 12 x 26
Application
Special feature
Halogen-free
Electrical data
Operating voltage [V] 10…36 DC
Protection class
II
Reverse polarity protection
yes
Outputs
Electrical design
PNP
Output function
normally open
Max. voltage drop switching output DC [V] 4
Minimum load current [mA] 5
Max. leakage current [mA] 1
Short-time current rating of switching output [mA] 2000; (only for mounting on a solid metal plate or cooling plate: 150 x 50 x 2 mm; Intermittent operation with a max. switch-on time of the load current of 4 s. ; After that a min. switch-off time of the load current of 2 s has to be kept.)
Switching frequency DC [Hz] 70
Detection zone
Sensing range [mm] 4
Real sensing range Sr [mm] 4 ± 10 %
Operating distance [mm] 0…3.25
Accuracy / deviations
Correction factor
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -10…10
Operating conditions
Ambient temperature [°C] -25…80
Protection
IP 67
Mechanical data
Weight [g] 143
Housing
rectangular
Mounting
non-flush mountable
Dimensions [mm] 40 x 12 x 26
Materials
PBT
Displays / operating elements
Display
switching status
1 x LED, yellow
Remarks
Pack quantity
1 pcs.
Electrical connection
Connection
Cable: 3 m, PUR, Halogen-free; 2 x 0.5 mm²