Product characteristics
Electrical design
PNP/NPN
Output function
normally open / normally closed
Communication interface
IO-Link
Application
Operating principle
dynamic; (static; bistable parameterisable)
Electrical data
Operating voltage [V] 10…30 DC
Current consumption [mA] 30
Protection class
III
Reverse polarity protection
yes
Outputs
Electrical design
PNP/NPN
Output function
normally open / normally closed
Permanent current rating of switching output DC [mA] 150
Short-circuit protection
yes
Overload protection
yes
Response times
Response time [ms] 35
Software / programming
Parameter setting options
normally open / normally closed; PnP/nPn; statisch / dynamisch / bistabil / Ein- Ausschaltverzögerung; brightness; Aktivierungs- Operations- Inputfarbe; Sensitivität
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor: Type 0 Generic Profiled Sensor; Identification and Diagnosis; Fixed Switching Signal Channel
SIO mode
yes
Required master port type
A
Process data analogue
1
Process data binary
1
Min. process cycle time [ms] 3.5
Supported DeviceIDs
Type of operation
DeviceID
Default
1002
Operating conditions
Ambient temperature [°C] -20…80
Protection
IP 65; IP 67; IP 69K; (on the front)
Mechanical data
Weight [g] 80.5
Materials
housing: stainless steel (1.4305 / 303); active face: PA Grilamid TR 90UV
Displays / operating elements
Display
1 x LED, blue / green / red / magenta / yellow / white / orange
preset
switching status
green
operation
–
function
red
Accessories
Accessories (supplied)
lock nuts: 1
Gasket: 1
Accessories (optional)
symbol disc
Remarks
Pack quantity
1 pcs.
Electrical connection – plug
Connection
Cable: 0.3 m, PUR
Connection
Connector: 1 x M12