Product characteristics
Number of inputs and outputs
Number of digital outputs: 2
Factory setting
hydrous coolants; water; media similar to water
Probe length L [mm] 472
Application
Media
hydrous coolants; oils; oil-based media; water; media similar to water
Dielectric constant of the medium
> 2
Cannot be used for
extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applications
Maximum speed of the change of level [mm/s] 200
Tank pressure [bar] 0.5; (when mounting with mounting accessories: E43001 – E43007, E43019)
Coolants
Medium temperature [°C] 0…35; (with climatic tube E43101: 35…60 °C)
Oil
Medium temperature [°C] 0…70
Medium temperature short time [°C] 0…90; (