Product characteristics
Number of inputs and outputs
Number of digital outputs: 4
Probe length L [mm] 100…1600
Process connection
G 3/4 external thread
Application
Special feature
Gold-plated contacts
Installation
Operation only in conjunction with rod and coaxial pipe.
Media
hydrous coolants; oils; oil-based media; water; media similar to water
Dielectric constant of the medium
≥ 2
Cannot be used for
See the operating instructions, chapter “Function and features”.
Medium temperature [°C] 0…80
Tank pressure [bar] -0.5…4
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] 5
Overflow switch point OP [mm] 70…L-30
Hysteresis, OP [mm] 10
Accuracy / deviations
Repeatability [mm] ± 5
Switch point accuracy [mm] ± (15 + 0,5 % ); (% of the final value of the measuring range: L – 30 mm)
Operating conditions
Ambient temperature [°C] 0…60
Storage temperature [°C] -25…80
Protection
IP 67
Mechanical data
Weight [g] 402
Materials
stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT-GF20; PC; PEI; TPV
Materials (wetted parts)
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR-PPTA 20
Process connection
G 3/4 external thread
Displays / operating elements
Display
Display unit
3 x LED, green
switching status
4 x LED, yellow
level
alphanumeric display, 4-digit
parameter setting
alphanumeric display, 4-digit
Remarks
Notes
For 8-pole sockets the core colours are not standardised.; Please note the wiring of the sensor and the sockets (see data sheet).
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Contacts: gold-plated