Product characteristics
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0…793 gph
0…13.22 gpm
Process connection
threaded connection G 3/4 flat seal
Application
Special feature
Gold-plated contacts
Application
totaliser function; for industrial applications
Installation
connection to pipe by means of an adapter
Media
water; glycol solutions; coolants; oil
Note on media
low-viscosity oils with viscosity: 7…40 mm²/s (40 °C)
high-viscosity oils with viscosity: 30…68 mm²/s (40 °C)
Medium temperature [°F] 14…176
Pressure rating [bar] 16
Pressure rating [psi] 232
Electrical data
Operating voltage [V] 19…30 DC; (according to EN 50178 SELV/PELV)
Current consumption [mA] 100
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs
counter reset
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; pulse signal; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250; (per output)
Number of analogue outputs
1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Analogue voltage output [V] 0…10; (scalable)
Min. load resistance [Ω] 2000
Pulse output
flow rate meter
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range
0…793 gph
0…13.22 gpm
Display range
0…951 gph
0…15.86 gpm
Resolution
1 gph
0.02 gpm
Set point SP
1…793 gph
0.02…13.22 gpm
Reset point rP
0…791 gph
0…13.2 gpm
Analogue start point ASP
0…637 gph
0…10.62 gpm
Analogue end point AEP
156…793 gph
2.6…13.22 gpm
Max. flow rate
951 gph
15.86 gpm
In steps of
1 gph
0.02 gpm
Volumetric flow quantity monitoring
Pulse value
0.02…9000 * 10³ gal
In steps of
0.02 gal
Pulse length [s] 0,6…2
Temperature monitoring
Measuring range [°F] 14…176
Resolution [°F] 0.5
Set point SP [°F] 14…176
Reset point rP [°F] 14…176
Analogue start point [°F] 14…144
Analogue end point [°F] 46…176
In steps of [°F] 0.5
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range)
0,26 gpm)
Response times
Flow monitoring
Response time [s] 0.25; (dAP = 0)
Delay time programmable dS, dr [s] 0…50
Damping for the switching output dAP [s] 0…1
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 70 (Q > 1 gpm); (water)
Software / programming
Parameter setting options
Flow monitoring; quantity meter; Preset counter; Temperature monitoring
Operating conditions
Ambient temperature [°F] 14…140
Storage temperature [°F] -13…176
Protection
IP 67
Mechanical data
Weight [g] 1505.5
Materials
housing: AlMgSi0,5 anodised; Sealing: FKM; connector housing: brass Optalloy-plated; PA 6.6; cover film: PA
Materials (wetted parts)
stainless steel (1.4404 / 316L); FKM; PES; Centellen 200
Process connection
threaded connection G 3/4 flat seal
Displays / operating elements
Display
Display unit
5 x LED, green (gpm, gph, gal, °F, 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Accessories
Accessories (supplied)
sealings: 2, Centellen
Accessories (optional)
adapter for pipe: 1 x 1/2″ NPT, stainless steel, E40191
adapter for pipe: 1 x 1/2″ NPT, brass, E40154
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
sealing: only with supplied Centellen seals
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated