Product characteristics
Output signal
analogue signal; (configurable)
Measuring range
-0.005…0.1 bar
-5…100 mbar
-0.073…1.45 psi
-0.5…10 kPa
Process connection
threaded connection G 1 external thread Aseptoflex Vario
Application
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C] -25…125; (150 max. 1h)
Min. bursting pressure
30000 mbar
435 psi
3000 kPa
Pressure rating
4000 mbar
58 psi
400 kPa
Vacuum resistance [mbar] -1000
Type of pressure
relative pressure
No dead space
yes
MAWP (for applications according to CRN) [bar] 4
Electrical data
Operating voltage [V] 18…30 DC
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Integrated watchdog
yes
2-wire
Current consumption [mA] 3.5…21.5
Power-on delay time [s] 1
3-wire
Current consumption [mA]