Product characteristics
Measuring range
-40…90 °C
-40…194 °F
Process connection
bolt-on sensor 12 x 8,7 x 51 mm
Application
Special feature
Gold-plated contacts
Measuring element
1 x Pt 100; (to DIN EN 60751, class A)
Installation
surface mount RTD for solid bodies
Electrical data
Insulation rating [V] 2500; (insulation between sensor housing and internal structure of the sensor)
Protection class
III
Measuring/setting range
Measuring range
-40…90 °C
-40…194 °F
Accuracy / deviations
Accuracy [K] ± (0,15 K + 0,002 x |t|)
Response times
Dynamic response T05 / T09 [s] 9 / 15; (values for a flat aluminium surface (anodised) using a conductive heat paste; reference values for moving water : 10 / 24 (