Product characteristics
Output function
normally open / normally closed; (selectable)
Sensing range [mm] 15
Housing
threaded type
Dimensions [mm] M30 x 1.5 / L = 150
Electrical data
Operating voltage [V] 30…250 AC / 20…250 DC
Protection class
II
Reverse polarity protection
yes
Outputs
Output function
normally open / normally closed; (selectable)
Max. voltage drop switching output DC [V] 8
Max. voltage drop switching output AC [V] 10
Minimum load current [mA] 5
Max. leakage current [mA] 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC)
Permanent current rating of switching output AC [mA] 100; (150 (…40 °C))
Permanent current rating of switching output DC [mA] 100; (150 (…40 °C))
Short-time current rating of switching output [mA] 1000; (20ms / 0,5Hz)
Switching frequency AC [Hz] 10
Switching frequency DC [Hz] 10
Notes on switching frequency
only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proof
no
Overload protection
no
Detection zone
Sensing range [mm] 15
Sensing range adjustable
yes
Factory setting sensing range [mm] 15
Real sensing range Sr [mm] 15 ± 10 %
Accuracy / deviations
Correction factor
glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2
Hysteresis [% of Sr] 1…15
Switch point drift [% of Sr] -20…20
Operating conditions
Ambient temperature [°C] -20…60
Protection
IP 65; IP 67
Mechanical data
Weight [g] 151
Housing
threaded type
Mounting
non-flush mountable
Dimensions [mm] M30 x 1.5 / L = 150
Thread designation
M30 x 1.5
Materials
PBT; PA
Displays / operating elements
Display
switching status
1 x LED, yellow
Electrical connection
Required protection
miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.
Accessories
Accessories (supplied)
lock nuts: 2
Remarks
Remarks
Recommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity
1 pcs.
Electrical connection
Connection
terminals: 0.34…2.5 mm²; Cable sheath: Ø 5…9 mm; Cable gland: M20 X 1.5