Product characteristics
Output function
2 x normally open; (potential-free)
Sensing range [mm] 5; (with defined actuator)
Housing
rectangular
Dimensions [mm] 36 x 13 x 26
Application
Design
coded target
Type of operation
permanent operation
Electrical data
Operating voltage [V] 24 DC; (“supply class 2” to cULus)
Rated insulation voltage [V] 60
Protection class
III
Reverse polarity protection
no
Internal resistance (Ri) [Ω] 10; (1 W)
Outputs
Output function
2 x normally open; (potential-free)
Permanent current rating of switching output DC [mA] 50
Switching frequency DC [Hz] 150
Output data
Interface type A
Short-circuit proof
no
Max. capacitive load CL_max [nF] 20
Detection zone
Sensing range [mm] 5; (with defined actuator)
Safe switching-off distance s(ar) [mm] 15
Response times
Response time to safety request [ms] 10
Max. fall time [ms] 0.1
Max. make time incl. bounce [ms] 0.6
Operating conditions
Applications
class C to EN 60654-1 weatherproof application
Ambient temperature [°C] -25…80
Note on ambient temperature
operational life ≤ 87600 h
Ambient temperature [°C] 10…40
Note on ambient temperature
operational life ≤ 175200 h
Max. relative air humidity [%] briefly: 5…95 %; permanent: 5…70 %
Air pressure [kPa] 80…106
Max. height above sea level [m] 2000
Salt spray
no
Protection
IP 67; IP 69K; (protected cable laying)
Mechanical data
Weight [g] 130.5
Housing
rectangular
Mounting
non-flush mountable
Dimensions [mm] 36 x 13 x 26
Materials
PA
Tightening torque [Nm] 0.8…2
Accessories
Items supplied
coded target
Remarks
Remarks
In connection with a G150xS / AC4x2S type evaluation unit, it is possible to reach up to PL e (ISO 13849-1) or SIL cl 3 (IEC 62061)
Pack quantity
1 pcs.
Electrical connection – plug
Connection
Cable: 0.1 m, PVC, Ø 5 mm
Connection
Connector: 1 x M12