Product characteristics
Output function
2 x normally open, 1 x normally closed; (potential-free)
Sensing range [mm] 8; (with defined actuator)
Housing
rectangular
Dimensions [mm] 88 x 13.1 x 25
Application
Design
coded target
Type of operation
permanent operation
Application
for safety-related applications
Electrical data
Operating voltage [V] 24 DC
Rated insulation voltage [V] 60
Protection class
III
Reverse polarity protection
no
Internal resistance (Ri) [Ω] 10; (1 W)
Outputs
Output function
2 x normally open, 1 x normally closed; (potential-free)
Permanent current rating of switching output DC [mA] 50
Switching frequency DC [Hz] 150
Output data
Interface type A
Short-circuit proof
no
Max. capacitive load CL_max [nF] 20
Detection zone
Sensing range [mm] 8; (with defined actuator)
Safe switching-off distance s(ar) [mm] 20
Response times
Response time to safety request [ms] 10
Max. fall time [ms] 0.1
Max. make time incl. bounce [ms] 0.6
Operating conditions
Applications
class C to EN 60654-1 weatherproof application
Ambient temperature [°C] -25…80
Note on ambient temperature
operational life ≤ 87600 h
Ambient temperature [°C] 10…40
Note on ambient temperature
operational life ≤ 175200 h
Max. relative air humidity [%] briefly: 5…95 %; permanent: 5…70 %
Air pressure [kPa] 80…106
Max. height above sea level [m] 2000
Salt spray
no
Protection
IP 67; IP 69K; (protected cable laying)